Dairy Level Product Line

Anderson electronic level transmitters are designed to accurately and repeatedly monitor the liquid height in a variety of process and storage vessels from a minimum height of 30 inches up to a maximum of 100 feet. Weld-in shells are available to provide a truly flush diaphragm seal with the inside wall of the tank. A special "mini" level transmitter is also available for simple level control applications in balance tanks and CIP vessels. The completely electronic "Differential" level transmitter eliminates bulky, hard to handle capillaries that in the past were a requirement on pressure or vacuum vessels. Anderson also offers a complete line of single and multiple channel micro-based level monitors which feature programmable self-points and alarm relays, as well as direct (DH+) PLC compatibility.

If you would like to receive literature on any of the products below by mail please fill out our online form.

Non-Contact Radar Level Transmitter The TRL series - designed for the toughest level control applications in the sanitary processing market. The Frequency Modulated Continuous Wave (FMCW) technology of our TRL Level Transmistter enables this sensor to be unaffected by changes in temperature, specific gravity, steam, pressure and vacuum, all of which create issues with ultrasonic and differential pressure-based sensors.

Form AIC 5014:
Brochure | Data Sheet Order Form | Manual | Price Page |


The HB "mini" sensor has been specifically designed for use in simple level control applications such as balance tanks and CIP vessels. This product is made to stand up to direct wash-downs and wide variations in temperature ranges: one for tanks 20" - 60" (low) and the other for tanks 60.1" - 100" (high).

Form AIC 5005:
Brochure | Manual | Price Page |

Sanitary Liquid Level Transmitter (SL)
The newly enhanced Anderson SL transmitter line is designed for maximum reliability and performance in sanitary process and storage tanks. Now available with HART protocol the SL provides level solutions for a wide variety of inventory applications.

Form AIC 5006:
Brochure | Data Sheet Order Form | Manual | Price Page | Startup Guide | Tech Bulletin |

LD "Top Mount" Level Transmitter
Based on our SL "Driftless" Transmitter, this top mount variation easily replaces problematic devices such as ball floats, pneumatics, capacitance probes and magneto-strictive sensors.

Form AIC 5011:
Brochure | Manual | Price Page | Startup Guide |

LN Potentiometric Level Transmitter
A top mount insertion probe, the LN is designed with process control in mind. Ideal for filler bowls, balance tanks, and pressurized vessels, the LN is immune to pressure or temperature changes excelling in applications where pressure based sensors come up short.

Form AIC 5041:
Brochure | Price Page | Startup Guide |

LS Capacitance Point Level Switch
The LS provides level verification for a variety challenging sanitary applications. Minimally invasive, the LS is designed for both tank level detection and pipeline product monitoring. Suitable for many water-based fluids, the LS also detects minimally conductive and viscous or foamy media. Standard with a PNP transistorized output the LS easily wires directly to a PLC and is available with a LED for local level indication.

Form AIC 5044:
Brochure | Price Page | Startup Guide |

LB Point Level Probes for Conductive Liquid Applications
3-A approved sanitary point level. The LB provides up to four independent level points with probe lengths to 72". Paired with the LL switching module, the point level system allows choices of normally open or closed contacts and accommodates a broad variety of conductive media.

Form AIC 5037:
Brochure | Competitive Cross Over | Price Page | Startup Guide |

Conductivity-based, solid state Modules and Probes for on/off liquid level switching and alarming The typical Anderson conductance probe-type liquid level system consists of two major components, the switching "module" and a sanitary probe with one or more electrodes.

Form AIC 3663:
Brochure | Manual | Price Page |


Electronic Sanitary Differential Level Transmitter (TDL)
A fully electronic, differential pressure/level measurement system. It is designed to monitor levels in pressurized storage tanks, vacuum vessels, and surge tanks.

Form AIC 5012:
Brochure | Data Sheet Order Form | Manual | Price Page |

Pulse 100 - Single Channel Liquid Level Monitor
The Pulse 100 microprocessor based monitor is designed for those customers wishing to monitor liquid level in a single vessel.

Form AIC 3388:
Brochure | Manual | Price Page |

Liqui-Track Tank Level Monitoring Systems
The Liqui-Track 3200 can accept up to 32 inputs from linear and non-linear storage vessels. It features Allen-Bradley® DH+ digital communications for sending information throughout the plant network.

The Liqui-Track 800 can be ordered with one or two input modules to accommodate four or eight tanks and multiple output options. Available communications protocols include: Ethernet, DH-485, Devicenet with RS232 standard.

Form AIC 5007:
Brochure | Data Sheet Order Form | Manual - 3200 | Manual - 800 | Price Page | Tank Data Worksheet |

To read PDF files, you need Adobe Acrobat Reader, a free download